The service pack must be installed with with local Administrator rights. Die Installation des Service Packs muss mit lokalen Administratorrechten durchgeführt werden. Requirements for SP1: Existing installation of Smap3D Plant Design 2025 release version Voraussetzung für SP1: Vorhandene Installation von Smap3D Plant Design 2025 Release Version Supported CAD systems: Solid Edge 2024/2025 with latest maintenance pack SOLIDWORKS 2024/2025 with latest service pack Autodesk Inventor 2024/2025 with latest service pack ! IMPORTANT NOTE: This service pack ONLY updates Smap3D Plant Design 2025 clients (incl. License Client Manager). This service pack installation file (.EXE) is NOT suitable for reinstalling computers without an existing Smap3D Plant Design 2025 installation. ! WICHTIGER HINWEIS: Dieses Service Pack aktualisiert Arbeitsplätze mit bestehender Smap3D Plant Design 2025 Installation (inkl. License Client Manager). Diese Service Pack Installationsdatei (.EXE) ist NICHT geeignet für die Neu-Installation von Computern ohne eine bestehende Smap3D Plant Design 2025 installation. ============================================================== Contents SP1 (23.25.100.32): ============================================================== SP1 contains Smap3D Parts Management 21.25.200.5 (SP2) P&ID 24.0.4.9 Electrical 24.0.4.9 Smap3D Plant Design applications 23.25.100.32 ScanToCAD 2025.0.58 License Client Manager 10.25.0.73 *** ENHANCEMENTS *** Coordinate System Wizard 45260 Coordinate System Wizard application updated to use DevExpress controls Component Wizard 45261 Component Wizard application updated to use DevExpress controls VCWriter 45262 Virtual Characteristics Writer application updated to use DevExpress controls Piping 27953 Pipe specification editor - Added Branch Table tab 43835 Pipe specification editor - Added Reducer Table tab 45330 Abbreviation for Branch and Reducer table added to the Pipe Specification Common settings 45202 Changed appearance of auto filter rows in Pipe Specification Editor 45153 Improved change detection in Pipe Specification Editor on Content tab 45071 Non unique dialogue uses columns defined in Pipe Specification Editor 45472 Better handling of read-only pipe specifications in Pipe Specification Editor 45164 Added warning in Pipe Specification Editor for inconsistent values in pipe specification columns 44977 Improved updating of additional items flag in Pipe Specification Editor P&ID To-Do list 44438 The "Update Info in CAD" function for components also use PathToModel or PartProvider/PartID for replace Isometric 44769 Reducers in Isometric (drawings split by pipeline) can now be duplicated the same way as branching components 44637 New option to use comma as decimal point in Isometric formulas 43635 New option in Isometric to split drawings by subassembly 43496 New option in Isometric to output to subfolder of assembly folder *** Repaired bugs *** P&ID / Electrical SPID-1046 Fixed - Wrong Chinese texts for the name of tools Edit Symbols/Lines data fields SOD-2351 Fixed - Picking a wire with article data from the pick menu could cause a crash AUTO-8072 Crash when double clicking outside the grid on the accessory tab in Component data Piping 45527 Fixed - Pipe specification editor now honors the settings for additional provider's color 45477 Fixed - Crash in Pipe Specification Editor settings when CustomConfig folder does not exist 45427 Fixed - Pipe Specification Editor - some sub-key names were not displayed in content grid 45396 Fixed - Color and Face style assignment does not work 45315 Fixed - Pipe specification editor - when copying row in insulation tab with enabled bend radius from generated pipe the grid crashed 45242 Fixed - Mandatory pipe specification header parameters can be deleted 45241 Fixed - In Pipe Specification Editor Reduced Diameter value is hidden for rows with not reducing key name 45213 Fixed - Edit pipeline dialog looks not correct in some UIs with longer text strings comparing EN 45211 Fixed - Visual bug in Pipe Specification Editor progress bars that was present for some skins 45187 Fixed - Pipe Specification Editor - Improved handling of skin settings when opening new window in Pipe Specification Editor Isometric 45433 Fixed - Property "Revision Number" is not correctly read/written in Inventor Parts Management DB Administrator and Part Finder 45467 Fixed - Property "Revision Number" from Inventor is not read during registration of standard parts 45320 Fixed - Extending specific part causes error message about illegal characters in category 45432 Fixed - PartFinder and DBAdministrator does allow column ordering in list views 45439 Fixed - Exception is shown to user during work with variable parts